Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Mettler Toledo
Model
Mettler Toledo
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€1,250.00 
(€1,487.50 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 30,00 kg

Categories

Mettler Toledo Classic AL104 Analytical Balance Analysenwaage Waage 110g x 0.1mg

PROFCONTROL GmbH€1,250.00 
(€1,487.50 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag MY11 - Adapter for Pipettes calibration 11 ml-cover
Radwag MY11 - Adapter for Pipettes calibration 11 ml

MY11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the MYA microbalance. Set content: weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Vessel capacity: 11 ml Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
analytical balances, ultra microbalances, ultra & microbalances accessories, scales, pipettes calibration, pipettes, microbalances accessories, microbalances, balances accessories, balances, analytical balances accessories
People are watching right now:
Radwag PMV 50.5Y Moisture Analyzer-cover
Radwag PMV 50.5Y Moisture Analyzer

PMV 50.5Y moisture analyzer is an advanced solution for measurement of moisture content of samples c (more)ontaining significant amount of moisture (up to 100%). The drying process is carried out by means of microwaves which enable to evenly heat the whole sample’s volume. The PMV 50.5Y, when compared to standard moisture analyzers, significantly shortens the drying time. The PMV 50.5Y microwave moisture analyzer can be successfully used wherever materials containing large amounts of water are dried. These materials are, for example, dairy products, fish, meat, fruit products, syrups, creams or liquid resin. The sample is placed in the drying chamber on a glass fibre filter. At the bottom of the chamber there is one end of the waveguide from where the microwaves are emitted. Upon process start, microwaves are equally distributed on the filter’s surface and dry the sample. The moisture content is determined on the basis of the mass loss obtained during drying. A respective drying program is selected depending on sample mass and its chemical composition. The average duration of this process depends on the type and mass of used substance, and takes 1 to 10 minutes. In contrast, drying using the traditional halogen moisture analyzer takes 5 to 40 minutes. The PMV 50.5Y microwave moisture analyzer is equipped with a temperature sensor and enables to monitor device power in order to prevent exceeding the boiling point during the process. A preset microwave power is displayed on the indicator throughout the drying procedure. The PMV 50.5Y’s main features: intended for drying of samples containing significant amount of moisture (up to 100%), ultra-short drying time when compared to traditional moisture analyzers and standard drying methods, microwave-based solution, uniform heating of entire sample’s surface, complex database of drying programs, finish mode: manual, automatic, time-defined, user-defined, advanced reports, time and statistical graphs, easy operation due to a touch screen. The PMV 50.5Y moisture analyzer is based on an advanced-class Y series system intended for laboratory balances. Expanded 16 GB memory enables saving and storing sophisticated reports and time and statistical graphs. Wireless communication improves ergonomics and operation safety. Wi-Fi® enables sending data between the moisture analyzer and a mobile device. Large 10’’ touch screen guarantees comfort of operation. Proximity sensors ensure touch-free access to user-specified operations. For each purchase of the PMV 50.5Y moisture analyzer the customer is supplied with: 60 glass fibre filters of ø90 mm, a sample of sodium chloride 10% ± 0,5% to determine correctness of the operation at the workstation, a service concerning determination of drying parameters for five customer-selected samples carried out by RADWAG employee. The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. * All trademarks and registered trademarks are the property of their respective owners. Terminal 5Y in Microwave Moisture Analyzer With the 5Y terminal, microwave moisture analyzer PMV gain new capabilities and functionalities, such as: 10-inch display, Digital Weighing Auditor (DWA), uncompromised user verification, Ambient Light, hotspot, RFID*, Live Note voice and text notes, voice commands for the device, measurement history within the Handy Library, widgets. Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13,56 MHz

€16,196.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]