Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Edwards
Location
Hampton - United States
Price
$8,995.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Edwards T-Station 85H Wet Turbo Station ISO63, 100-120V

$8,995.00 (ex VAT)
item image

Description from the supplier

Edwards T-Station 85H Wet Turbo Station ISO63, 100-120V


Ultimate Pressure
<5 x 10-9 mbar
Inlet Connection
DN 63 ISO-K
Leak Tightness
<1 x 10-6 mbar ls-1

  • Single dedicated button to start/stop pumps; Easy to read accurate display
  • Base plate includes rubber feet and cut-outs in the sides for manual handling
  • The nEXT85 and nEXT300 turbomolecular pumps, XDD1 dry diaphragm pump and E2M1.5 backing pump are all user serviceable
  • Integrated air cooler acts to cool internal power supply and pump/controller for quiet operation avoiding multiple fans
  • All metal frame means rugged design that can take abuse without cracking or breaking
  • Inlet flange options - Available with either an NW40, ISO63 or CF63 inlet flange to suit your application
  • T-Station Pumping Station Base
  • E2M1.5 Rotary Vane Pump
  • nEXT85H Turbomolecular Pump with ISO63 Inlet
  • All Necessary Tubing and Cables for Turn-key Operation
  • Operator's Manual
  • 1 Year Manufacturer's Warranty

Product details

Ultimate Vacuum<5 x 10 -9 mbar
Pumping Speed84 ls -1
Compression ratio for N 2>1x10 11
Backing pump speed 50Hz1.6 m 3 h-1
Inlet FlangeDN 63 CF
Exhaust flange11 mm nozzle / 3/8" BSPP (G) Female
Noise level db(A)<56 ± 3dB(A) Declared dual number noise emission values in
Leak tightness<1x10 -6 (mbar l/s-1)
Operating temperature range12 to 40°C
Dimensions (LxWxH)15.55 x 13.78 x 10.63 in. (39.5 x 35.0 x 27 cm)
Electrical Requirements1Ph 100-120V 50/60Hz
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Mixed Job Lot of Laboratory Equipment - Meti, Bio-Rad, Grant, Hitachi, Jenway
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Mixed Job Lot of Laboratory Equipment - Meti, Bio-Rad, Grant, Hitachi, Jenway NOTE - THIS IS A SPARES/REPAIRS ITEM

Mixed Job Lot of Laboratory Equipment This job lot of items comes from a variety of university labor (more)atories. The items were no longer required, collected from various store rooms and facilities. None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well. None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks. They are sold as a spares/repairs bundle and further investment in each individual product may be required. It is an excellent opportunity for anyone looking to benefit from individual equipment resale. The units have not been tested at all. ITEM-37281 METI Silent Pistol Compressor compact 106ITEM-37291 HP Series 1050 VW DetectorITEM-37293 Jenway 3020pH MeterITEM-37294 Savant PS 250ITEM-37295 Hitachi CP-X3011 ProjectorITEM-37296 DaynaPort E/ZITEM-37297 Denley We Warm 1ITEM-37298 Unifet microprocessor ph/mv/ºc meter with isfet sensorITEM-37299 3x Electrophoresis Plastic ContainersITEM-37300 Stuart Scientific Gyro-RockerITEM-37301 DaynaPort E/ZITEM-37302 Scie-Plas Electro-Blotting UnitsITEM-37303 American Optical Spencer 820 Microtome W/ 820 Knife Blade Holder Lab EquipmentITEM-37304 Box of electophoresis plastic containersITEM-37306 Kerry Water BathITEM-37307 Powervar ABCE800-22 Power SupplyITEM-37308 Grant Y28 Water BathITEM-37309 6x Bunsen BurnersITEM-37310 Pharmacia LKB Pump P-1ITEM-37311 Bio-Rad Mini-Sub Cell GTITEM-37313 Grant ss40-dITEM-37314 Bio-rad 583 Gel DryerITEM-37315 Olympus VMT MicroscopeITEM-37316 Epson WP-4015 PrinterITEM-37317 1x Bunsen BurnerITEM-37337 DailyTop UV Disinfection LampITEM-37338 2x VWR Maxi 20 Electrophoresis HorizontalITEM-37346 Polymer Laboratories PL-AS RT GPC Auto Sampler LabITEM-37357 Unicam 4815 Computing IntegratorITEM-37358 Vickers Instruments MicroscopeITEM-37359 DailyTop UV Disinfection LampITEM-37360 Vickers Instruments MicroscopeITEM-37366 Vickers Instruments MicroscopeITEM-37367 Vickers Instruments MicroscopeITEM-37369 Vickers Instruments MicroscopeITEM-37370 Vickers Instruments Microscope

£500.00 ex VAT
United Kingdom
clinical laboratory equipment other, general laboratory equipment other
Polyscience MX28P100-A11B 28L Polycarbonate Open Bath, MX (Ambient +10 to 85C), 120V, 60Hz-cover
Polyscience MX28P100-A11B 28L Polycarbonate Open Bath, MX (Ambient +10 to 85C), 120V, 60Hz

Polyscience MX28P100-A11B 28L Polycarbonate Open Bath, MX (Ambient +10 to 85C), 120V, 60HzFeatures - (more) Large, universal icon and English display - On-screen prompts - Single-point calibration capability - Working temperatures from ambient +10° up to 150°C - DuraTop™ insulating, chemical-resistant top deck - Temperature stability of ±0.07°C - Controller displays internal bath temperature, set-point and more–all on one easy to read screen Three control buttons and plain-text on-screen prompts make the setup and operation of the MX Temperature Controller easy and straightforward. Redundant over-temperature protection, high and low temperature limits and alarms alert you instantly to conditions that fall outside normal operating parameters User-settable high-temperature safety provides over-temperature and low liquid level protection. Patented, integrated design protects pump and heater while simplifying cleaning and maintenance. PolyScience Circulating Bath with MX Temperature Controller. It is intended for the precise temperature control of suitable liquids in a reservoir. Extremely easy to use and maintain, it combines design innovation with highly intuitive operation to deliver convenient and versatile liquid temperature control for a wide range of applications. Click Here to View Product Video INCLUDED: The Polyscience MX28P100-A11B 28L Polycarbonate Open Bath, MX (Ambient +10 to 85C), 120V, 60Hz includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$2,402.00 ex VAT
United States
general laboratory equipment other
People are watching right now:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€8,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]