Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Location
Hampton - United States
Price
$298.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Benchmark H5000-15 Block, 35 x 1.5ml

$298.00 (ex VAT)
item image

Description from the supplier

  • Manufacturer's Documentation
  • 2 Year Manufacturer's Warranty
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Edwards T-Station 300 Dry Turbo Station ISO100 mXDS3s, 115V-cover
Edwards T-Station 300 Dry Turbo Station ISO100 mXDS3s, 115V

Edwards T-Station 300 Dry Turbo Station ISO100 mXDS3s, 115V Ultimate Pressure 6.000 × 10⁻⁸ Pumping  (more)Speed for H2 280 ls-1 Inlet Connection DN 63 ISO-K Features - Compact, powerful and reliable performance… wherever you need it - NOW also with the latest mXDS3s scroll pumps providing the best efficiency and best performance of the turbomolecular pump. - Push button vacuum stations ready to go - Designed to be used straight from the box our T-Station's do not require systemisation or complex configuration. - User servicable - The nEXT85 and nEXT300 turbomolecular pumps, mXDS3 dry scroll pump, XDD1 dry diaphragm pump and E2M1.5 backing pump are all user serviceable - Inlet flange options - Available with either an NW40, ISO63 or CF63 for T-Station 85 and ISO100 and CF100 for T-Station 300 inlet flange to suit your application The Edwards Turbomolecular Pumping Stations are meticulously designed to provide a comprehensive and user-friendly vacuum solution, incorporating the latest technological advances for seamless installation and operation. These pumping stations are versatile, catering to a wide range of applications. Choose from a range of turbomolecular pumping stations, including the entry-level T-Station 85 and the higher capacity T-Station 300.Experience top-tier vacuum solutions with High Vacuum Pump Systems. Edwards offers cutting-edge technology and versatility to enhance your operations. Upgrade your vacuum system today and enjoy seamless performance in a variety of applications.The T-Station 300 builds on the existing popular T-Station 85 platform, by replacing the nEXT85H with the nEXT300 turbomolecular pump providing a solution for customers and applications that require a higher pumping speed up to 300 ls-1. Click Here to View Product Video INCLUDED: The Edwards T-Station 300 Dry Turbo Station ISO100 mXDS3s, 115V includes: - T-Station Pumping Station Base - Edwards mXDS3s Dry Scroll Pump - nEXT300 Turbomolecular Pump with ISO100 Inlet - All Necessary Tubing and Cables for Turn-key Operation - Operator's Manual - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$14,139.00 ex VAT
United States
general laboratory equipment other
Julabo CORIO CD-B39 Open Bath Heating Circulator, 115V/60Hz (NRTL Certified)-cover
Julabo CORIO CD-B39 Open Bath Heating Circulator, 115V/60Hz (NRTL Certified)

Julabo CORIO CD-B39 Open Bath Heating Circulator, 115V/60Hz (NRTL Certified) Working Temperature Ran (more)ge 20°C to 150°C Heating Capacity 1000W Fluid Type Water, Silicone Features - Models for internal and external applications - Bright, white, easy to read display - Very quiet - Easy pump change-over between internal and external circulation - USB connection - High-quality bath tanks made of stainless steel - Integrated drain screw (except B5 model) The Julabo CORIO™ CD Immersion Heating Circulator Open Bath combinations with transparent or stainless steel bath tanks for routine laboratory tasks. Units include bright LED display and easy operation. The CORIO™ CD immersion circulator provides temperatures to 100°C in plastic tanks and to 150°C in stainless steel tanks. Integrated pump enables temperature incubation for internal or external bath applications. A lever below the display enables simple adjustment between internal and external flow. Pump capacity: 15 L/min; 5.1 PSI. The integrated USB port provides external PC communication for control / monitoring and data logging. Stainless steel tanks from 13 to 39L include a drain port. INCLUDED: The Julabo CORIO CD-B39 Open Bath Heating Circulator, 115V/60Hz (NRTL Certified) includes: - 2 Each Barbed Fitting for Tubing 8 and 12 mm Inner Dia. (Pump Connections M16x1 Male) - Power Cord - Operator's Manual - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$5,151.00 ex VAT
United States
general laboratory equipment other
Büchi Reveleris X2 Flash Chromatography System-cover
Büchi Reveleris X2 Flash Chromatography System

The Reveleris X2 Flash Chromatography System is designed for the rapid purification of complex sampl (more)es by liquid chromatography. A flash chromatographic separation is performed using a cartridge containing a stationary phase such as 40-63µm silica and a mobile phase such as hexane: ethyl acetate (70:30) at a flow rate of 40mL/min at a moderate pressure (typically less than 100 psig). Although the resolution of flash chromatography is less than that of analytical or preparative high performance liquid chromatography (HPLC), where 2-5 µm particles are employed, the technique is extremely useful as it provides the chromatographer with the ability to separate gram size samples in a short period. In flash chromatography, as in analytical or preparative HPLC, the separation is a function of the relative interaction of the various compounds in the sample with the stationary phase and the mobile phase. Compounds with a stronger interaction with the stationary phase than with the mobile phase will be more strongly retained by the column and have a longer retention time (and vice versa). Typically, the chromatographer determines the general conditions for separation of the sample via thin layer chromatography (TLC). Although most flash chromatography separations are performed using a normal phase cartridge, a number of other stationary phases are available. The Reveleris X2 Flash Chromatography systems include a UV detector that can monitor three wavelengths simultaneously as well as an evaporative light scattering detector (ELSD). The ELSD provides the ability to monitor all non-volatile compounds in the mobile phase and allows the user to detect for compounds that do not absorb UV radiation. An additional benefit of the ELSD is the ability to employ mobile phases that absorb light at the same wavelength as the compound(s) of interest. Both detectors offer adjustable sensitivity settings to detect and collect small and large quantity of compounds. Mode of Operation: Gradient Flash Chromatographic System Solvent Delivery System: 4 Independent channels Gradient Formation: Binary Gradient with High Pressure Mixing Flow Rate: 1-200mL/min Flow Rate Accuracy: ± 3% (4-200mL/min) Maximum Pressure: 200psig Gradient accuracy (at 40mL/min): ± 1.5% Gradient precision (at 40mL/min): < 1% Sample Modes: Liquid or Solid Sample Modes Sample Loader: Sample loaders for 3g, 25g, and 60g can be employed Sample Loader Plunger: Three sizes (15mL, 75mL, and 150mL). Absorbance Detector Wavelength Range 200 – 500 nm Number of Wavelengths monitored: 3 wavelengths can be monitored and used to trigger fraction collection ELSD Detector Light Source: Laser (0.3mW) Detector Element: Silicon Photodiode Fraction Collection Triggers: UV signal, ELSD signal Collection Racks: Multi position racks for 36x 25 mm tubes

€19,999.00 ex VAT
Netherlands
general laboratory equipment other
People are watching right now:
Edinburgh Instruments Time Correlated Single Photon Counting System-cover
Edinburgh Instruments Time Correlated Single Photon Counting System

Edinburgh Instruments Time-Correlated Single Photon Counting System This system was removed from a u (more)niversity lab where it was surplus to requirements. Although all units successfully powered on, we cannot test it completely at our facility. Condition varies as stated below each item. The system includes the following components: Edinburgh Instruments Spectrometer SystemSerial#: 178 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the control box, PMT Cooler Controller &amp; PC with Software. The following tests were conducted: 1. Excitation Mono Successfully Initialised2. Emission1 Mono Successfully Initialised3. Excitation Polariser Successfully Initialised4. Emission1 Polariser Successfully Initialised5. Sample Holder Temperature Successfully Read6. nF Iris did not initialise (nF Iris Cable present but unable to find port)7. TAC Range &amp; Scaler Successfully Initialised All tests were performed using CD900 Test software. However, unable to open EAI Level 2 Edinburgh Instruments CD900 Software due to requiring Software Protection Device. Additionally, the system includes: Edinburgh Instruments Nanosecond Flashlamp HeadModel: nF900Serial#: 095Mfd: 03/2000 The item is in good cosmetic condition and pairs successfully with the Spectrometer System. Edinburgh Instruments nF900 ControllerModel: nF900Serial#: 092Mfd: 03/2000 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the Spectrometer System, PMT Cooler Controller &amp; PC with Software. All cables shown at the rear are included. Edinburgh Instruments CD900 ControllerModel: CD900Serial#: 112Mfd: 03/2000 The item is in good cosmetic condition with all components present. It powers on and successfully pairs with the Spectrometer System, PMT Cooler Controller &amp; PC with Software. All cables shown at the rear are included. Lastly, the system includes an Elonex ProSentia PC, iiyama ProLite B2290HS Monitor, Elonex Keyboard &amp; Microsoft. All items are in good cosmetic condition and in full working order. The PC runs Windows 98 and the software installed includes EAI Level 2 (requires Software Protection Device), F900 test, and Cd900t (requires Software Protection Device).

£5,000.00 ex VAT
United Kingdom
software development
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]