Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Perkin Elmer
Model
Perkin Elmer 200
Supplier
Used Lab Machines Ltd
Location
Walton-on-the-Naze - United Kingdom
This item is
Not available
State of item
used
Categories

Perkin Elmer Series 200 HPLC System

Used Lab Machines Ltd
item image

Description by the supplier

This listing is for a Perkin Elmer Series 200 HPLC Systems


Including the

Perkin Elmer Series 200 Peltier Column Oven

Perkin Elmer Series 200 Autosampler

Perkin Elmer Series 200 LC Pump

Perkin Elmer NCI 900 Network Chromatography Interface

Perkin Elmer 600 Series Link Chromatography Interface

ESA Electrochemical detetctor

Bottle HolderEquipment can be serviced/renovated/refurbished on request at extra cost.

About Used Lab Machines Ltd

Used Lab Machines Ltd is a family business that is actively buying and selling used laboratory and medical equipment. We offer a wide range of instruments and brands and models from leading manufacturers.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Envirco MAC 10 Fan Filter Unit-cover
Envirco MAC 10 Fan Filter Unit

The Envirco MAC 10 fan filter unit, was the first (FFU) to combine low sound, low watts and a low pr (more)ofile. Measuring only 51 dBA, the MAC 10 Original Standard (600 mm x 1210 mm) provides one of the lowest sound levels of any FFU in the industry. Running at only 310 watts at 90 fpm, the unit uses less energy than traditional FFUs, lowering operating costs. The MAC 10 Original maintains a low profile, measuring less than 330 mm. MAC 10 Original comes standard with the filter integral with the unit housing, requiring the unit to be removed from the ceiling grid to replace the filter. The RSR unit has the filter sealed to the unit using the knife edge/gel seal construction, allowing the filter to be replaced from the roomside. The RSRE unit has the added feature of allowing the motor blower and filter to be replaced from the roomside. Low sound, low watts, low profile, and low operating costs. Three speed switch features low, medium, and high settings; standard on all 2 ft x 4 ft units Solid state speed controller standard on 2 ft x 2 ft, 2 ft x 3 ft, and all RSR units. Forward-curved centrifugal fan. High Efficiency Particulate Air (HEPA) UL900 Filter: 99.99% efficient at 0.3 Micron. Snap-in prefilter allows for easy replacement and maintenance. Walkable Plenum (excluding prefilter), rated at 250 lbs. Mill finished aluminum exterior. Tested to IEST recommended standards. Caution this is a 110 Volt instrument.

€999.00 ex VAT
Netherlands
filtration supplies
Radwag TMX15IR.6.H2.K Multifunctional Scale-cover
Radwag TMX15IR.6.H2.K Multifunctional Scale

Multifunctional scales TMX H is designed to fast and precise determination of mass in industrial con (more)ditions. TMX H Multifunctional scales TMX H comprises terminal PUE 5 and a weighing platform. Labelling system series TMX H is used to print labels for marking weighted goods e.g. in the process of packing. The program can generate standard labels for single goods. Functionality of the software: a function of weight control (weighing control + / -), previewing weighments carried out on weighing terminal as a table of weighments, simplified reporting module allowing the report to be generated, creation of label templates from labels in weighing terminal, identification of goods by using the code EAN-13 and EAN-128, quick search using the range of barcode scanner, the availability of databases: the operators, products, clients, warehouses, tares (packages), etc. The application enables measurements execution and their record into a local database or on the server. Networked terminals allow transmission of the measurements to the parent database installed on the server. The ability to work with a computer program E2R SYSTEM. Terminal types: PUE 5.15R, PUE 5.19R &ndash; resistive touch screen technology. Protection class IP68. High resistance to moisture and dust. In comparison to remaining models, limited brightness and lower resistance to shocks and scratches. Possibility of operation using gloves preventing scratches (latex, material). PUE 5.15IR, PUE 5.19IR &ndash; infrared touch screen technology. Protection class IP68. Very high brightness and readability level. High resistance to moisture and dust. High mechanical resistance, possibility of operation using gloves (made of latex, material or even steel chain). PUE 5.15C, PUE 5.19C &ndash; capacitive touch screen technology. Protection class IP68. High brightness and readability level. High resistance to moisture and dust, good mechanical resistance. Absolute precision of touch detection, sensing multiple points of touch (multi-touch).

€5,040.00 ex VAT
Poland
platform scales
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]