Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
JASCO
Model
JASCO J-1500
Supplier
LabMakelaar Benelux B.V.
Location
Zevenhuizen - Netherlands
Price
€3,999.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Jasco 1500 HPLC System

LabMakelaar Benelux B.V.€3,999.00 (ex VAT)
item image

Description by the supplier

System consists of:


Jasco UV-1570M Intelligent UV Detector


Jasco LG-1580-02 Ternary Gradient Unit


Jasco PU-1580 Intelligent HPLC Pump


Jasco AS-1555 Intelligent Sampler


2 Alltech Elite Degassing System


PC

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: 2 Solvent cabinets 2 Capillary pumps 1 Well-plate samplers 2 Autosampler thermostat (more)s 1 Thermostatted colomn compartment 1 Diode array detector 1 Handheld control module Vacuum degasser cel is missing in the vacuum degasser Capillary pump: Settable column flow range: 0.01 – 20 µl/min Recommended column flow range: 1 – 20 µl/min Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) Optimum composition range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting Delay volume: Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Pressure range: 20 to 400 bar (5880 psi) system pressure Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. Well-plate sampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Autosampler thermostat: Temperature range: setable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient temperatures < 25 °C and humidity < 50%: – 1°C to + 4 °C at a setpoint of 4 °C Temperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%: – 1°C to + 5 °C at a setpoint of 4 °C Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. Handheld control module: The control module provides complete local control and monitoring of a single module or an entire Agilent series system. There is no data evaluation in the control module. The control module allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses.

€9,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Julabo CORIO CD-450F Refrigerated Circulator with Natural Refrigerant (R290), 115V/60Hz-cover
Julabo CORIO CD-450F Refrigerated Circulator with Natural Refrigerant (R290), 115V/60Hz

Julabo CORIO CD-450F Refrigerated Circulator with Natural Refrigerant (R290), 115V/60Hz Refrigerant  (more) R290 Working Temperature Range -30°C - 150°C Cooling Capacity 450W (at 20°C) Features - Models for internal and external applications - Bright, white, easy to read display - Very quiet - Easy pump change-over (internal and external circulation) - External pump connections (M16x1) - USB connection - Space-saving cooling coil design yields more usable space in the bath tank - Bath lid and drain tap included - Removable ventilation grid - Refrigeration unit without side vents - Class III (FL) according to DIN 12876-1 CORIO™ CD-450F refrigerated/heating circulator with an operating range of -30…+150 °C and ±0.03 °C stability. Suitable for temperature applications with cirulation to an external apparatus or immersing a device in the bath tank. The CORIO™ CD circulator incorporates easy change-over for control of fluid circulation internally or externally. The CORIO CD includes USB-B port for PC communication and a USB-A port for datalogging. Unit fittings: M16x1 male threaded adapters including a pair of 8 and 12 mm hose barbs. 450W cooling power at 20 °C with 70W at -30 °C. Options for heating power (1kW or 2kW) and refrigerant (R290 natural refrigerant or R449A synthetic refrigerant).Class III (FL) according to DIN 12876-1.INCLUDED: The Julabo CORIO CD-450F Refrigerated Circulator with Natural Refrigerant (R290), 115V/60Hz includes: - 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) - Power Cord - Two Year Manufacturer's Warranty

$7,810.00 ex VAT
United States
general laboratory equipment other
Nasco Life/form Advanced Venipuncture and Injection Arm-cover
Nasco Life/form Advanced Venipuncture and Injection Arm

This revolutionary training arm provides complete venous access for IV therapy and phlebotomy, plus  (more)sites for intramuscular and intradermal injections. An extensive 8-line vascular system allows students to practice venipuncture at all primary and secondary locations, including starting IVs and introducing Over the Needle IV Catheters. The venous system simplifies setup with only one external fluid bag supplying artificial blood to all veins simultaneously. The dorsal surface of the hand includes injectable metacarpal, digital, and thumb veins. The antecubital fossa includes the median cephalic, median basilic, and median cubital veins. Venipuncture can also be performed along the basilic, cephalic, accessory cephalic, and median antebrachial veins. Intramuscular injections may be performed in the deltoid muscle and intradermal injection sites are located in the upper arm. Intramuscular injections into the deltoid muscle are enhanced by the soft, lifelike skin and by the natural bony landmarks in the region. Intradermal injections using distilled water will create characteristic skin welts at designated sites on the upper arm. The realism of the Life/form® Advanced Venipuncture and Injection Arm is truly amazing. The soft, flexible fingers are molded separately with extreme attention paid to every detail – right down to the fingerprints! Flexion of the wrist helps students develop manipulation skills. The replaceable skin rolls as the veins are palpated, and a discernible pop is felt when entering the veins. The Life/form® molding process reproduces the fine details of the skin to make the arm look and feel alive. Valves in the veins can be seen and palpated on the skin surface. Simulated veins and skin are completely replaceable to keep this training arm looking and working like new. Under normal use, hundreds of injections may be performed before the veins or skin need to be replaced. Complete replacement kits are available and easy to use. To extend the life of the veins, an aerosol sealant is available to seal punctures and prevent leakage.Includes 2 uarts of simulated blood, 3 cc syringe, 12 cc syringe, needle, two fluid bags, instruction manual, and soft carry case.

€1,499.00 ex VAT
Netherlands
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]