Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Agilent
Model
Agilent 1260
Supplier
Lab2
Location
Berkel en Rodenrijs - Netherlands
This item is
for sale
State of item
used
Categories

Agilent 1260 Nano HPLCAgilent 1260 series HPLC

Lab2
item image

Description by the supplier

Agilent 1260 series HPLC

For sale: Refurbished Agilent 1260 series HPLC system including:

Prices from: 20.000,- till 25.000,-

1260 series qu- degasser (G1379B)

1260 series Nano Pump (G2226A)

1260 series HIP micro ALS (G1377A)

1260 series TCC (G1316A)

1200 series DAD (G1315D)

Also available:

Agilent 1100 and 1200 series with DAD, FLD, RID Detectors

Agilent 1100 and 1200 series modules

In combination with MS systems from Agilent, Thermo, Siecx, Waters, Shimadzu

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

For sale: Refurbished Agilent 1260 series HPLC system including:

Prices from: 20.000,- till 25.000,-

1260 series qu- degasser (G1379B)

1260 series Nano Pump (G2226A)

1260 series HIP micro ALS (G1377A)

1260 series TCC (G1316A)

1200 series DAD (G1315D)

Also available:

Agilent 1100 and 1200 series with DAD, FLD, RID Detectors

Agilent 1100 and 1200 series modules

In combination with MS systems from Agilent, Thermo, Siecx, Waters, Shimadzu

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

About Lab2

LAB2 is specialized in refurbishment or used analytical instruments of the major brands, like Agilent Tech, Thermo, Waters, Shimadzu, Perkin Elmer, CTC Analytics, Varian and more. Through the years we have developed into one of the most reliable partners worldwide.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser Binary pump Autosampler Thermostatted colomn compartme (more)nt Variable wavelength detector Vacuum degasser: The Agilent 1100 HPLC Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Binary pump: Flow Precision: <0.3 % RSD (typically <0.15 % RSD) Flow Range: Setpoints from 0.001 to 5.0 ml/min,  in 0.001 ml/min increments Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) Pulsation: <2 % amplitude (typically <1 %) at 1 ml/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi) Compressibility compensation: User selectable, based on mobile phase compressibility Delay volume: 180 – 480 µl (600-900 µl with mixer) dependent on back pressure Recommended pH range: 1.0 – 12.5. Solvents with pH <2.3 should not contain acids which attack steel Well-plate autosampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl  Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Variable wavelength detector: Detection type: Double beam photometer Light source: Deuterium lamp Wavelength range: 190 – 600 nm Wavelength accuracy: ± 1 nm Bandwidth: 6.5 nm Linearity:> 2AU (5%) upper limit Flow cell standard: 14 µl volume, 10 mm cell path length, 40 bar

€7,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]