Agilent GC/MS with 5973N MSD and 6890 GC

item image

Description from the supplier

For sale: Refurbished Agilent GCMS system including:
Prices from: 15000 till 18000 euro (please ask for official quote)
6890N GC with split/splitless inlet
5973N MSD with turbo pump
Masshunter software
Computer
7683 sampler with 100 vial tray
Edwards roughing pump
Test report
Tune report
Warranty

Also available:
Agilent 5793N with 7890 GC
Agilent 5975 MSD systems

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!
We can deliver maintenance and repair services for GC/MS by our own engineers

Agilent GCMS specifications

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
SRI 8610C GC Gas Chromatograph System Lab-cover
SRI 8610C GC Gas Chromatograph System Lab

Reason for return - Investigate faults and re-list accordingly: - We received the item with a cracke (more)d glass piece to the photoionization detector. We replaced it with a piece that was provided. - We piped the system with N2 carrier gas and gas lines carrying product to the inlet of the GC. We turned on the switch to the Photoionization detector, under high sensitivity, and can visibly see it turn on. The source is aligned. The detector is aligned.  - We programmed the event on the software to turn the valve of the 10-way valve accordingly to enable the carrier gas to bring the product through the GC. - We introduced acetone via the sample loop (inlet gas) - we saw no peaks. We introduced acetone via injection - we saw no peaks.  - I leaked checked the piping including within the detector - no issues. I checked the point of outlets to make sure flow is continuous too - no issues. - The mechanism of the valve turning - it made a cranky sound, and I am not convinced it is turning the valve.  - There may be two issues. I had figured it was the valve so I tried injecting acetone directly into the line, but we could not see any peak of acetone. (Issues with the detector?) I am not sure if the valve's squeaking/cranky sound implies it is turning but there might be an issue here too. This SRI 8610C GC Gas Chromatograph System was removed from a university lab where it was surplus to requirements. The unit powers up but we were unable to test it further at our facility. The lab did confirm however, that is in good working order. It is in very good cosmetic condition with only very minor marks from use.

£1,540.00 ex VAT
United Kingdom
gc systems
People are watching right now:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€8,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]