Easily list your scientific equipment
Top suppliers for laboratory & industry
New and used instruments
Memmert IF260plus Forced Circulation Incubator 256L, 115V
Working Temperature Range
Min. 10°C above ambient up to +80°C
Convection Type
Forced Air
Chamber Volume
256 L (9 cu.ft.)
Features
- Setting temperature range from +20°C to +80°C with 0.1°C accuracy
- Volume of 256 L (9 cu.ft.) with easy-to-clean stainless steel interior
- Temperature control via 2 Pt100 sensors Class A in 4-wire-circuit for mutual monitoring
- TwinDISPLAY adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-color displays
- Forced air circulation with adjustable fan speed in 10% steps and pre-heated fresh air admixture
- AutoSAFETY with integrated over- and undertemperature monitor, plus mechanical temperature limiter TB
- Function SetpointWAIT ensures the process begins only after the set temperature is reached
- Sterilization program for chamber cleaning at 160°C for 4 hours
The Memmert IF260plus Forced Circulation Incubator 256L, 115V offers precise temperature control within a range from Min. 10°C above ambient up to +80°C, with a 0.1°C accuracy, making it ideal for highly sensitive lab applications. Featuring a spacious 256 L (9 cu.ft.) stainless steel interior, this incubator is designed for easy cleaning and durability. The TwinDISPLAY adaptive multifunctional digital PID-microprocessor controller with dual high-definition TFT-color displays allows for precise control over various parameters, including temperature, fan speed, and program time.
Equipped with AutoSAFETY features, the IF260plus ensures over- and undertemperature protection, along with a mechanical temperature limiter TB for added safety. Forced air circulation is adjustable in 10% steps, with pre-heated fresh air admixture for optimal performance. The Function SetpointWAIT ensures the process only begins once the set temperature is achieved, providing reliable and consistent results. Additionally, the unit includes a sterilization program that cleans the chamber at 160°C for 4 hours, offering efficient maintenance between uses. This incubator is well-suited for demanding lab environments requiring precision and reliability.
INCLUDED:
The Memmert IF260plus Forced Circulation Incubator 256L, 115V includes:
- 2 Stainless Steel Grids
- Tilt Protection Wall Bracket
- Calibration Certificate
- Power Cord
- Operator's Manual
- Manufacturer's Documentation
- 3 Year Manufacturer's Warranty
Setting Temperature Range | +20 to +80°C |
Working Temperature Range | Min. 10°C above ambient up to +80°C |
Setting Accuracy (temperature) | 0.1°C |
Volume | 256 L (9 cu.ft.) |
Temperature Sensor | 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over performance |
Control Panel | ControlCOCKPIT: Adaptive multifunctional digital PID-microprocessor controller with 2 high definition TFT-Color displays |
Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
Adjustable Parameters | Temperature (Celsius or Fahrenheit), fan speed, air flap position, program time, time zones, daylight savings time |
Sterilization Program | Fixed sterilization program (4 hours/160°C) for sterilizing the working chamber (not the load) |
Function SetpointWAIT | The process time does not start until the set temperature is reached |
Language Setting | German/English/Spanish/French |
Calibration | Three freely selectable temperature values |
Fan | Forced air circulation by quiet air turbine, adjustable in 10% steps |
Fresh Air Admixture | Adjustment of pre-heated fresh air admixture by air flap control in 10% steps for each segment |
Vent | Vent connection with restrictor flap |
Documentation | Program stored in case of power failure |
Temperature Control | Adjustable overtemperature monitor TWW, adjustable temperature limiter TWB, mechanical temperature limiter TB (protection class 1 DIN 12880) |
AutoSAFETY | Integrated over- and undertemperature monitor "ASF", automatically following setpoint value at a preset tolerance range |
Autodiagnostic System | For fault analysis |
Door | Fully insulated stainless steel door with 2-point locking (compression door lock), inner glass door |
Interior | Easy-to-clean stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides |
Max. Number of Shelves | 9 |
Max. Loading Per Shelf | 44 lbs |
Max. Loading of Chamber | 661 lbs |
Interior Dimensions (WxHxD) | 25.2” x 31.5” x 19.7” (64 x 80 x 50 cm) |
Exterior Dimensions (WxHxD) | 32.4” x 46.6” x 26.9” (82.4 x 118.3 x 68.4 cm) |
Net Weight | Approx. 243 lbs |
Electrical Data | 115 V, 50/60 Hz, approx. 900 W |
QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.
Customer Service
Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.