Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
WAT
Location
Potsdam - Germany
Price
€5,000.00 
(€5,950.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 55,00 kg

Categories

WAT Wagner Analyse Technik IRIS 2 II Infrarot 13C Stabilisotopen Analysesystem

€5,000.00 
(€5,950.00 incl. VAT* )* - if applicable
item image

Description from the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Varian DS 102 Two-stage Rotary Vane Pump SQ 396 SP + Oil Mist Eliminator KF 25-cover
Varian DS 102 Two-stage Rotary Vane Pump SQ 396 SP + Oil Mist Eliminator KF 25

Manufacturer: Varian Model: DS 102 Two-stage Rotary Vane Pump + Oil Mist Eliminator KF 25 949-9395 s (more)erie S/N: 219579 Description: Thanks to a very simple and highly reliable design, this field proven DS Series rotary vane pump provides excellent vacuum performance. The quality and manufacturing standards ensure that the DS rotary vane pumps provide high pumping stability for light gases, low noise, minimal oil backstreaming, and a long operating life. The pump’s two-stage design allows for low operating temperature, minimal backstreaming at low pressure and good pumping efficiency and gas ballast. It delivers a pumping speed of max. 114 liters per minute, low noise and a long operating life. It conforms to European Union directives (CE) and Restriction of Hazardous Substances (RoHS) requirements, and it is also UL and Canadian Standards Authority (CSA) approved. Oil Mist Eliminator KF 25 949-9395 serie is assembled at the outlet of the rotary pump and the main purpose is to purify the exhaust gases from oil mists. The use is advised for pumps which have to work for a long time at intake pressures exceeding 10 mbar, or with the ballasting tap open. Applications: - Analytical Instruments:Dual Stage Rotary Vane Pumps are practically the only primary vacuum pumps used on GC-MS and MALDI-TOF Instruments:GC-MS typically uses this small pump - the pump is needed to rough the system and back the high vacuum Turbo or Diffusion pump. MALDI-TOF depending on system size, uses the DS102 as roughing or interface pump.- Leak Detection:DS102 is typically used to back the Helium Mass Spectrometer Turbo or Diffusion pump.- Industrial Vacuum Processes:Vacuum coatings, Metallurgy Vacuum Furnaces, Lamps and TV Tube manufacture, Sterilizers, Freeze Dryers, Glove Boxes, High Speed Centrifuges, and Flywheels (for energy storage) represent the main Industrial applications for Dual Stage Rotary Vane pump. - High Energy Physics and Research Laboratories:In these applications the Rotary Vane pumps are mainly used in combination with Turbo pumps. The combination is typically used to rough and pump High Vacuum experimental chambers or to start Ion Pumps in ultra high vacuum systems.Features: - Dual Stage Pump:The two stage design allows low 10-3 mbar operation, low operating temperature, minimal backstreaming at low pressure, good pumping efficiency and gas ballast in the high 10-3 mbar region.- Forced Oil Circulation:The dedicated oil circulation gear pump ensures efficient and reliable lubrication of the pump from atmospheric pressure throughout the entire vacuum operating range.- Built-in Oil Shield:This feature minimizes the oil mist at the pump exhaust. Apart from drastically reducing the oil consumption over long periods of operation, this results in a reduction of air pollution limiting the impact on the environment. Specifications: Free air displacement:- 60 Hz: 114 l/min (4 cfm)- 50 Hz: 95 l/min (5.7 m3/h)Pumping speed:- 60 Hz: 3.5 cfm- 50 Hz: 5 m3/hUltimate partial pressure: 10-4 mbarUltimate total pressure: 2 x 10-3 mbarUltimate total pressure with gas ballast: 2 x 10-2 mbarWater vapor tolerance: 15 mbarWater vapor capacity: 60 g/hOil capacity min/max: 0.2/0.5 lMotor rating 1ph:- 60 Hz: 0.55 kW- 50 Hz: 0.45 kWNominal rotation speed:- 60 Hz: 1800 rpm- 50 Hz: 1500 rpmInlet flange: 25KF DNExhaust flange: 25KF DNOil Mist Eliminator's pneurop fitting: KF 25Oil Mist Eliminator's material: Nylon 30VF Items delivered: - Varian DS 102 Two-stage Rotary Vane Pump + Oil Mist Eliminator KF 25 949-9395 serie Condition: The whole item is in used but good condition. It is 100% functional tested and ready to be operated.

€600.00 ex VAT
€714.00 incl. VAT if applicable
Germany
analytical devices other, vacuum pumps
People are watching right now:
Grass Technologies PS33-Plus Photic Stimulator-cover
Grass Technologies PS33-Plus Photic Stimulator

Refurbished Photic Stimulator. 6 months warranty* Scope of delivery: - Photic Stimulator - Photic Ar (more)m - Roll Stand - Table clamp - User Manual Features: - Consistent Flash Characteristics: Accurate stimulus parameters - Wide Intensity Range: Extended appplications - Wide Flash Rates: Provides variable stimulus rates - Synchromous inputs/Outputs: Active High/Low TTL inputs/outputs simplify interfacing Technical data: - Flash Mode: Single or repetitive flashes - Flash Intensity: 5 steps with ratios of 1,2,4,8,16. 22 lumen sec/ft2 at intensity 16 maximum energy (1.44 joules). - Flash Rate: 1 to 60 per second, ‡5% accuracy - Flash Duration: 10 uS - Flash Tube: Xenon - Monitors Front panel monitor light, flashes only when flash lamp lights. Two output pulses suitable for low frequency display devices. - Synchronous Inputs: External control of flash rate via TTL level sync pulse. External control of intensity via TTL logic levels. - Synchronous Output: TTL level, 20 us pulse for high frequency devices, signal averager, oscilloscope, etc. - Power: 115 or 230 VAC, 50/60 Hz, 150 VA maximum Physical Size: - 9.75" W x 5.375" H x 8.1875" D (24.8cm x 13.7cm x 20.8cm) - Weight: 12 lbs. (5.4kg) - Flash Lamp: 5.375" diameter (13.7cm), 5" depth (12.7cm) - Handle: 4" long (10.2cm), 1.25" diameter (3.2cm) - Cable Length: 12-foot (3.6m) Environmental Specifications: - Operations: 0 to 40°C, 10 to 90% RH - Non-condensing - Storage: -20 to 60°C - Pressure: 800 to 1,040 hPa Regulatory: - 115VAC: Certified to CAN/CSA C22.2 - No. 1010.1. Conforms to UL3101-1. - 230VAC: CE Mark to IEC-1010-1.G * No warranty on the light bulb.

€1,150.00 ex VAT
Germany
neurology or eeg or emg, medical pumps
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]