Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Parker Hannifin / Balston
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€200.00 
(€238.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 3,00 kg

Categories

Parker SMH42600 Motor brushless 200V Q 12050005

PROFCONTROL GmbH€200.00 
(€238.00 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Waters 2998 DAD PDA Photodiode Diode Array Detector 2695 2795 HPLC 186002998-cover
Waters 2998 DAD PDA Photodiode Diode Array Detector 2695 2795 HPLC 186002998

Manufacturer: Waters Model: 2998 Photodiode Array (PDA) Detector P/N: 186002998 S/N: H08998 002A De (more)scription: The Waters 2998 Photodiode Array (PDA) Detector for Purification and Modular LC Systems offers advanced optical detection, providing unprecedented trace impurity detection and quantitation in conjunction with spectral analysis capabilities. It is the ideal detector for any laboratory application, from compound identification to method development. For routine analyses, the 2998 PDA detector is reliable, easy-to-use, and has enhanced software control to provide flexibility for simultaneous 2D and 3D operation. Features: - Patented TaperSlit flow cell ensures high sensitivity while maintaining optimal spectral performance- Low noise performance of <10 µAU- Wide, linear dynamic range with constant optical bandpass- Simultaneous quantification of high- and low-level components within a single chromatographic separation- Flexible sampling rates for normal and fast LC separations from 1 to 80 Hz- Independent optimization of sampling rate and time constant gives you the ability to tune your detector to your separation goals- Definitive compound identification & co-elution detection- Spectral exposure optimization to maximize the signal-to-noise across the entire wavelength range with a single Deuterium lamp- Lamp optimization for the best s/n performance over the lifetime of a Deuterium lamp- Console software for simple control, monitoring, and diagnostics- Thermal wander management for maximum baseline stability- Flow cell options to match your separation scale and type Specifications: Electrical requirements and power supply:- 100-240 V- 50/60 Hz- 185 VA- F 3.5A / 250V Items delivered: - Waters 2998 Photodiode Array (PDA) Detector Condition: The Waters 2998 Photodiode Array (PDA) Detector is in very good cosmetic as well as working and technical condition. It is 100% functional tested and ready to be applied.

€5,000.00 ex VAT
€5,950.00 incl. VAT if applicable
Germany
electronics
Large safety cabinet for lithium batteries with one door LITHIUMSAFE CHEMISAFE-cover
Large safety cabinet for lithium batteries with one door LITHIUMSAFE CHEMISAFE

LITHIUMSAFE SAFETY CABINETS Certifications: EN 14470-1 EN 16121 The line of LITHIUMSAFE safety cabin (more)ets consists of innovative high quality products, built in Italy and specifically built for the safe storage of lithium batteries. These cabinets are designed according to current standards and can be equipped with numerous accessories for further levels of safety. COSTRUCTION Completely built in electro-galvanized steel sheet, cold pressed with removable external structure; thicknesses of 1/1.5/2 millimeters and painting with anti-acid epoxy powders and passage in a thermal tunnel at 200°C. Particular insulation on the panels for high temperatures (800°C): calcium silicate and mineral fiber (fibroceramic free) at high density 300 Kg/m3 fixed with ceramic adhesives. Fireproof melamine laminate panels with high resistance to even aggressive vapours. Certification according to EN 14470-1 and EN 16121 standards. CHARACTERISTICS - AUTOMATIC CLOSING of the door in the event of temperatures exceeding 47°C - LOCK AND LOCK OF THE DOORS WITH KEY - Certified automatic closing SYSTEM (70/100 °C) of the air inlet and outlet ducts, maintenance-free, placed on the back of the cabinet. - Ejection HOLE diam. 100mm. at the back of the wardrobe - Anti-spark hinge in natural iron with brass pin. - 1 shelf perforated at the base - 3 cm thermo expanding GASKET. (DIN 4102) - 'Earth' CLAMP to prevent electrostatic charges. ACCESSORIES Q90: QUARANTINE PATENTED extinguishing system with tank for 90cm model FBN: automatic fire extinguisher FPC: automatic fire extinguisher with control panel, smoke and temperature sensor, beacon S6MT: UNEL 220V 6-position electrical multiple socket with thermal protection. S6: UNEL 220V 6-position electrical multiple socket. RIPF90VL: metal shelf, 695x420x39mm INTAKE SYSTEMS DIAM125BP: electric aspirator CSF100BPAMY11: ATEX electric fan CFN: molecular aspiration system certified according to standard NFX15-211 For more information on the products and safety systems available, we invite you to our dedicated post 'LITHIUMSAFE'.

€1,796.00 ex VAT
€2,137.24 incl. VAT if applicable
Italy
electronics
People are watching right now:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]