Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
MA 50.5Y.IC.NS Moisture Analyzer
Location
Radom - Poland
Price
€3,826.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag MA 50.5Y.IC.NS Moisture Analyzer

€3,826.00 (ex VAT)
item image

Description from the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

It Dries in 4 Ways

The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.

The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.

You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.

The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.

The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C.

How Do I Finish the Drying? In 4 Ways

The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.

Automatic mode
You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.

Manual mode
You terminate the measurement yourself by pressing the STOP button.

Time-defined mode
The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!

User-defined mode
When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Digital Weighing Auditor

Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags*that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?

We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

Full data security

Electronic signatures

Validations

Electronic records

Audit trails

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

*RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details

FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag F2 Mass Standard - Stainless Steel Wire - 200 mg-cover
Radwag F2 Mass Standard - Stainless Steel Wire - 200 mg

F2-class mass standards represent an impressive level of precision in mass measurement. Classified a (more)s metrology grade F2, they are recognized as top-quality tools suited for advanced applications where precision is a key element. F2 mass standard: stainless steel wire Nominal value: 200 mg Material: stainless steel Exceptional Measurement Precision F2 class mass standards feature excellent measurement precision achieved through stringent standards for allowable deviation from actual weight. Stability under Dynamic Conditions An important feature of F2-class mass standards is their ability to maintain measurement stability even under dynamic measurement conditions. They are designed to cope with a variety of factors that affect measurement precision. Calibration at the Highest Level The calibration process of F2-class mass standards adheres to the most stringent norms and standards. This makes the standards of this class recognized as tools with the highest degree of accuracy, complying with international requirements. Use of Materials with Outstanding Properties F2 class mass standards are often constructed from materials with outstanding physical properties. This ensures not only excellent precision, but also exceptional durability. Application 1. Scientific Research at the Highest Level In scientific research, especially in fields that require the utmost precision, such as nuclear physics or astrophysics, F2 class mass standards are indispensable. 2. Metrology Industry In metrology laboratories engaged in testing and maintaining the most advanced measurement standards, F2 class standards are indispensable working tools. 3. High-Precision Testing Laboratories In laboratories specializing in research requiring the highest precision, such as forensic laboratories and materials testing, F2 class mass standards are essential. 4. Aerospace Industry In the precision mass measurements required in the aerospace industry, F2 class standards provide reliability and excellence. F2 class mass standards are the symbol of the highest precision in the field of mass measurement. Their use is crucial in the most advanced fields of science, industry and research.

€34.00 ex VAT
Poland
mass standards
Radwag WLY 6/F1/R Precision Balance-cover
Radwag WLY 6/F1/R Precision Balance

If you buy a WLY series balance by July 31, 2024, you will receive each of these products along with (more) a FREE lifetime license for the Workflow Module. Precision Balance WLY Fast and accurate weight determination thanks to the duo: the WLY multifunction balance and the PUE7 weighing terminal. Ease of operation and maximum automation of the weighing process. Not just weighing But also parts counting, checkweighing, percent weighing, animal weighing, formulations and differential weighing. The power of WLY’s working mods. Use the potential Barcode scanners, receipt printers, label printers, RFID readers, PC equipment or an additional weighing platform – thanks to multipurpose software, WLY balance can work with all of them. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. The Workflow Module will improve work in your company. It enables developing a path of customized weighing process adapted to individual requirements of a particular production system, and next sending it to all weighing instruments cooperating with the E2R. The given process is started on the weighing instrument upon operator logging or after selecting a product, a formulation or an ingredient to which it is assigned. Modifications are made with use of convenient and intuitive interface. DIY with WLY With WLY you will Do It Yourself: You will program on-screen keys and functional keys You will program infrared proximity sensors You will design printouts You will design text data that is displayed in an indicator display. This balance is the result of a combination of our experience and true precision. Want to generate labels? You can. With Label Editor software, you will generate: Standard labels for single products C labels for cumulative containers CC labels for containers with cumulative containers. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€1,634.00 ex VAT
Poland
balances, precision balances
People are watching right now:
MARSHALL Select MS-PA20UL Autoclavable Pipette, 2-20ul-cover
MARSHALL Select MS-PA20UL Autoclavable Pipette, 2-20ul

MARSHALL Select MS-PA20UL Autoclavable Pipette, 2-20ul Volume Range 2 to 20ul Increment 0.5ul Pipett (more)e Type Manual Air Displacement Features - Adjustable from 2 to 20 µl for versatile small to medium sample processing - Offers 0.5 µl increments for precise volume adjustments in detailed experiments - Ensures accurate measurements with an accuracy of ±0.9/1.20/3.00% for critical applications - Provides consistent results with a precision of ±0.4/1.00/2.00% to enhance experiment reproducibility - Serializable at 121°C without special preparation, maintaining sterility and performance - Low-force design reduces fatigue and minimizes risk of repetitive strain injuries - Easy to maintain for long-term reliable performance in the lab The MARSHALL Select MS-PA20UL Autoclavable Pipette is a highly precise and ergonomic tool designed for various laboratory applications requiring accurate liquid handling. With a volume range of 2 to 20 µl and a fine 0.5 µl increment, this pipette offers exceptional accuracy of ±0.9/1.20/3.00% and precision of ±0.4/1.00/2.00%, making it ideal for delicate and small-volume tasks. Its lightweight design and low-force mechanism reduce the risk of repetitive strain injuries, ensuring user comfort during prolonged use. The centrally located digital display enhances ambidextrous usability, making it easy for both left- and right-handed users to view volume settings. A rotating counter knob allows for quick volume adjustments, while a quick-release pipette tip ejector facilitates convenient tip changes. Constructed from innovative materials, the MS-PA20UL is easy to calibrate and maintain, ensuring reliable performance over time. This pipette is fully autoclavable at 121°C, allowing for thorough sterilization without the need for special preparation. After autoclaving, it can be cooled and dried over 12 hours, ready for immediate use. The design helps avoid repetitive strain injuries and includes a volume lock to prevent accidental adjustments. It is compatible with universal pipette tips and suitable for both forward and reverse pipetting techniques, offering versatility for handling low-viscosity liquids and more challenging higher-viscosity or foamy samples. As part of a comprehensive range covering volumes from 0.1 µl to 10 ml, the MS-PA20UL provides flexibility across different applications. With robust construction and user-friendly features, this pipette is an indispensable tool for laboratories seeking precision and reliability in liquid handling, meeting rigorous standards including ISO 9001:2008 and ISO 13485:2003 certifications, along with CE marking. INCLUDED: The MARSHALL Select MS-PA20UL Autoclavable Pipette, 2-20ul includes: - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$151.00 ex VAT
United States
autoclaves or sterilizers, pipettes
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]