Radwag MA 210.5Y Moisture Analyzer

€3,620.00 (ex VAT)
item image

Description from the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

It Dries in 4 Ways

The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.

The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.

You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.

The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.

The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C.

How Do I Finish the Drying? In 4 Ways

The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.

Automatic mode
You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.

Manual mode
You terminate the measurement yourself by pressing the STOP button.

Time-defined mode
The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!

User-defined mode
When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Digital Weighing Auditor

Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags*that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?

We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

Full data security

Electronic signatures

Validations

Electronic records

Audit trails

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

*RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details

FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Ohaus EX223 Explorer Toploading Balance, 220 g, 0.001 g-cover
Ohaus EX223 Explorer Toploading Balance, 220 g, 0.001 g

Ohaus EX223 Explorer Toploading BalanceThe OHAUSEX223 Explorer Precision Balance with 220 gram weigh (more)t capacity, has newlyoptimized linearity and repeatability specifications and enhanced vibrationfiltering for better balance stability. All Explorer models also come standardwith AutoCal automatic internal calibration. These combined enhancementsimprove accuracy, efficiency, and throughput.A large colortouch-screen display, icon-driven application software that features 14 uniqueapplication modes, and an adjustable angle display make the OHAUS Explorerseries the easiest to use, most advanced balance in its class today.The base andterminal of the Explorer EX223 separate for maximum flexibility in any workarea. It also has four user-programmable touch free sensors to minimize crosscontamination and button wear. The EX223 meet or exceed the Class I and IIaccuracy requirements in accordance with the National Institute of Standardsand Technology (NIST) Handbook. 220g Capacity 0.001g Readability Platform: 130mm Large 5.7" full-color touchscreen display with intuitive set-up and application software AutoCal automatic internal calibration for optimized weighing performance 14 application modes, 11 weighing units and 5 display languages for a wide variety of applications 4 programmable touchless sensors for hands-free operation Modular display can be separated from the weighing base Frameless draftshield with anti-static glass, flip-top and large side entry doors on top-mounted bearings Click Here to View Product Video INCLUDED: The Ohaus EX223 Explorer Toploading Balance includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$3,007.00 ex VAT
United States
balances
Ohaus PX124/E Pioneer Analytical Balance, 120 g, 0.0001 g-cover
Ohaus PX124/E Pioneer Analytical Balance, 120 g, 0.0001 g

Ohaus PX124/E Pioneer Analytical BalanceThe OhausPX124/E Pioneer PX Analytical Balance combines esse (more)ntial weighing functionalitywith competitive performance, offering high accuracy and repeatability forapplications in laboratory, industrial and education settings with internalcalibration. The PX124/E weighing plate has a maximum capacity of 120 gramswith a readability of 0.0001 grams and a weight stabilization time of 3 seconds.The PX124/E is affordably priced, intuitively designed for intelligent operationwith a second line display for additional information, and USB and RS-232connectivity for easy communication. 120 gram weight capacity Readability (grams): 0.0001 Pan size (diameter): 90 mm Stabilization Time: 3 seconds External Calibration Model The PX offers high accuracy and repeatability for essential weighing applications in laboratory, industrial and education settings at an economical price point Featuring a cast metal lower housing, sub-pan and stainless steel weighing pan, the PX is durably constructed for versatile, long-term use The PX features a second line display for additional information or guidance Static removal bar for convenient grounding USB and RS-232 connectivity for easy communication Click Here to View Product Video INCLUDED: The Ohaus PX124/E Pioneer Analytical Balance includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$2,139.00 ex VAT
United States
scales, balances
Ohaus AX125D Adventurer Semi-Micro Analytical Balance, 82 g/120 g, 0.00001 g/0.0001 g-cover
Ohaus AX125D Adventurer Semi-Micro Analytical Balance, 82 g/120 g, 0.00001 g/0.0001 g

Ohaus AX125D Adventurer Semi-Micro Analytical Balance, 82 g/120 g, 0.00001 g/0.0001 g Maximum Capaci (more)ty 82 g / 120 g Readability 0.00001 g / 0.0001 g Repeatability (Typical) 0.00002 g / 0.0001 g Features - AutoCal™ ensures precise, consistent calibration with no manual effort - Compact draftshield provides easy access and reduces bench space - 4.3" touchscreen offers intuitive controls and adjustable brightness - USB ports enable seamless data transfer and regulatory compliance - Stainless steel pan ensures long lasting durability across research applications - Power-saving features reduce energy use and operational costs - Real-time clock supports GLP/GMP compliance with accurate timestamps - User management secures data with three customizable access levels The Ohaus AX125D Adventurer Semi-Micro Analytical Balance, 82 g/120 g, 0.00001 g/0.0001 g, delivers precise and reliable performance for a wide range of weighing applications. Featuring AutoCal™ technology, it ensures consistent calibration with minimal effort. Its compact draftshield design optimizes workspace efficiency, while the 4.3" full-color touchscreen provides an intuitive and customizable user experience. Dual USB ports enable easy data transfer and support compliance with regulatory standards. Additional highlights include power-saving features, a real-time clock for GLP/GMP compatibility, and a three-level user management system, making it a versatile and dependable tool for laboratories, educational institutions, and industrial settings.INCLUDED: The Ohaus AX125D Adventurer Semi-Micro Analytical Balance, 82 g/120 g, 0.00001 g/0.0001 g includes: - Wind Ring - Draftshield - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$5,695.00 ex VAT
United States
scanning electron microscopes, balances, electron microscopes, scales
People are watching right now:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser Binary pump Autosampler Thermostatted colomn compartme (more)nt Variable wavelength detector Vacuum degasser: The Agilent 1100 HPLC Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Binary pump: Flow Precision: <0.3 % RSD (typically <0.15 % RSD) Flow Range: Setpoints from 0.001 to 5.0 ml/min,  in 0.001 ml/min increments Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) Pulsation: <2 % amplitude (typically <1 %) at 1 ml/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi) Compressibility compensation: User selectable, based on mobile phase compressibility Delay volume: 180 – 480 µl (600-900 µl with mixer) dependent on back pressure Recommended pH range: 1.0 – 12.5. Solvents with pH <2.3 should not contain acids which attack steel Well-plate autosampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl  Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Variable wavelength detector: Detection type: Double beam photometer Light source: Deuterium lamp Wavelength range: 190 – 600 nm Wavelength accuracy: ± 1 nm Bandwidth: 6.5 nm Linearity:> 2AU (5%) upper limit Flow cell standard: 14 µl volume, 10 mm cell path length, 40 bar

€7,999.00 ex VAT