Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
MA 110.5Y.IC Moisture Analyzer
Location
Radom - Poland
Price
€3,940.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag MA 110.5Y.IC Moisture Analyzer

€3,940.00 (ex VAT)
item image

Description from the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

It Dries in 4 Ways

The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.

The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.

You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.

The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.

The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C.

How Do I Finish the Drying? In 4 Ways

The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.

Automatic mode
You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.

Manual mode
You terminate the measurement yourself by pressing the STOP button.

Time-defined mode
The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!

User-defined mode
When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Digital Weighing Auditor

Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags*that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?

We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

Full data security

Electronic signatures

Validations

Electronic records

Audit trails

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

*RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details

FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag F1 Mass Standard - Flat Polygonal Sheet - 1 mg-cover
Radwag F1 Mass Standard - Flat Polygonal Sheet - 1 mg

F1 class mass standards are exceptional measuring tools that represent the pinnacle of precision in  (more)the field of metrology. Classified as F1 metrology class, they are perfect for advanced applications where every detail of measurement is of paramount importance. F1 mass standard: flat polygonal sheet Nominal value: 1 mg Material: aluminum F1 Class Mass Standards – Key Features Highest Precision and Accuracy - F1 class mass standards are characterized by absolute measurement precision and extraordinary accuracy. They are designed to meet the most stringent standards for acceptable deviation from actual weight. Stability under Difficult Conditions - An important feature of F1 class mass standards is their ability to maintain measurement stability even under harsh environmental conditions. The standards of this class are resistant to changes in temperature, humidity and other factors that affect the precision of measurements. Calibration in Accordance with International Standards - The calibration process for F1-class mass standards is rigorous and in accordance with international standards. This ensures that standards of this class are globally recognized and can be used in different countries. Specialized Construction Materials - F1-class standards are often made of materials with unique physical properties. This provides them not only with precision, but also with durability and wear resistance. Application 1. Industrial Metrology F1 class mass standards are used in metrology laboratories engaged in the testing and maintenance of measurement standards. 2. Scientific Research In scientific research, especially in high-precision fields such as physics and astronomy, F1-class mass standards are a key tool. 3. Aerospace Industry In the precision mass measurements required by the aerospace industry, F1-class standards guarantee reliability and accuracy. 4. Calibration Laboratories In calibration laboratories where uniformity and precision are a priority, F1-class mass standards are the standard of excellence. F1-class mass standards are synonymous with the highest quality and precision in the field of metrology. Their use is crucial where even the slightest deviation from the standard can carry unpleasant consequences. They are tools for advanced applications that contribute to raising standards in the field of mass measurement.

€18.00 ex VAT
Poland
mass standards
People are watching right now:
Radwag HX5.EX-1.4.60.C7 4 Load Cell Platform Scale-cover
Radwag HX5.EX-1.4.60.C7 4 Load Cell Platform Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€4,986.00 ex VAT
Poland
platform scales, scales for ex areas
Radwag HX5.EX-1.4.3000.H8 4 Load Cell Platform Scale-cover
Radwag HX5.EX-1.4.3000.H8 4 Load Cell Platform Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€6,894.00 ex VAT
Poland
platform scales, scales for ex areas
Matrix Thermo Scientific 8-Channel Equalizer electr. Pipette 5-250 µl 2032-11-cover
Matrix Thermo Scientific 8-Channel Equalizer electr. Pipette 5-250 µl 2032-11

Manufacturer: Matrix / Thermo Scientific Model: 8-Channel Equalizer Pipette, 5-250 µl (P/N 2032-11)  (more)Description: Expandable Tip SpacingThe Matrix Equalizer pipette's tips can be spaced anywhere from 9 mm (96-well microplates) to 14.15 mm (12-13 mm tube rack spacing or 48-well plates) in increments of 0.1 mm. The distance between tips is always equal— simply set the desired spacing anywhere on the scale and pull or push the rod to expand or contract the tips. This can be done while the tips are empty or full, enabling the quick and easy transfer of multiple samples at once between labware with different configurations. Tip Spacing Down to 4.5 mmThe Matrix Equalizer 384 pipette features the same unique tip spacing mechanism but allows you to set the tip spacing down to 4.5 mm—perfect for multichannel dispensing from 96-well plates into 384-well plates or for multi-lane sample loading of agarose gels. The 8-channel expands to 14.15 mm, the 12-channel to 9 mm. Ergonomic DesignLight and well-balanced, the pipette design keeps your hand close to the pipetting surface and incorporates a highly leveraged tip ejector that utilizes two or three fingers (and not the thumb). Light Tip Application and EjectionDesigned in conjunction with Thermo Scientific Matrix pipette tips, ensure superior tip fit with minimal application/ejection forces

€400.00 ex VAT
€476.00 incl. VAT if applicable
Germany
pipettes accessories, pipettes calibration
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]