Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
Tweezers 160 mm for mass standards up to 200 g
Location
Radom - Poland
Price
€30.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag Tweezers 160 mm for mass standards up to 200 g

€30.00 (ex VAT)
item image

Description from the supplier

Convenient Transportation of Small Mass Standards

The mass standards tweezers are tongs/ pliers that will enable you to conveniently and precisely grasp and transport small mass standards. With it, you can easily and quickly place or lay an object (for example, a mass standard) on the pan and remove it from the pan. The tweezers protect the mass standards from finger grease, moisture and other factors that interfere with the measurement. It is indispensable in the daily use of laboratory balances.

Tweezers 160 mm

Material: stainless steel
with a silicone tip

for standards up to 200 g

What Kind of Tweezers for Mass Standards?

TWEEZERS

LENGHT

APPLICATION

Standard

105 mm

up to 50 g

160 mm

up to
200 g

250 mm

up to
500 g

300 mm

up to
500 g

Made of carbon fiber

105 mm

up to 50 g

With a carbon fiber tip

105 mm

up to 50 g

155 mm

up to
200 g

185 mm

up to
200 g

200 mm

up to
200 g

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V-cover
Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V

Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V Working Temperature Range At least  (more)10°C above ambient to +250°C Setting Resolution (Temperature) Up to 99.9°C: 0.1°C / From 100°C: 0.5°C Chamber Volume 161L (5.68 Cu. Ft.) Features - Working temperature range from at least 10°C above ambient to +250°C - Volume capacity of 161L (5.68 Cu. Ft.) with stainless steel interior - TwinDISPLAY with adaptive multifunctional digital PID-microprocessor controller and dual high-definition TFT-color displays - Forced air circulation adjustable in 10% steps, with pre-heated fresh air admixture - AutoSAFETY system with integrated over- and undertemperature protection - Supports up to 8 shelves with a maximum chamber load of 462 lbs - Three freely selectable temperature calibration points - Function SetpointWAIT ensures process begins only once set temperature is reached The Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V offers advanced precision and reliability with a working temperature range from at least 10°C above ambient to +250°C. Designed with a spacious 161L (5.68 cu.ft.) interior, this oven features a stainless steel chamber reinforced with deep-drawn ribbing, providing both durability and ease of cleaning. The TwinDISPLAY control system, equipped with two high-definition TFT-color displays, allows for adaptive multifunctional temperature management, ensuring accurate control via two Pt100 sensors in a 4-wire circuit for mutual monitoring. Additional features include forced air circulation, adjustable fan speed in 10% increments, and pre-heated fresh air admixture for optimal thermal distribution. For enhanced safety, the Memmert UF160TS includes the AutoSAFETY system, which provides integrated over- and undertemperature protection, as well as a mechanical temperature limiter (TB) that switches off heating at 20°C above the nominal temperature. The Function SetpointWAIT ensures the process begins only once the set temperature is reached, while the Function HeatBALANCE allows precise adjustment of heating performance. With a maximum loading capacity of 462 lbs, spread across up to 8 shelves, this oven is ideal for demanding laboratory applications requiring consistent, reliable performance. INCLUDED: The Memmert UF160TS Forced Circulation Pass-Through Oven 161L, 115V includes: - 2 Stainless Steel Grid - Tilt Protection Wall Bracket - Base Cladding with Screw Connection - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$13,947.00 ex VAT
United States
ovens, heating & cooling, furnaces
Chiller ULK 1002 FRYKA-cover
Chiller ULK 1002 FRYKA

Cooling recirculator model ULK 1002 FRYKA The universal chiller for laboratory and industry, charact (more)erized by its flexibility in various applications. A great economical alternative to running water cooling systems. The 9.5-liter tank allows for wide-ranging methods of use: when full, it ensures high temperature stability over time and, at a minimum, a rapid cooling system for the most immediate needs. The new modern space-saving design, low weight, innovative technical features with low-noise cooling unit, also make it suitable for direct use at the workplace. Energy efficient: - fan with EC technology Low noise level: - particularly quiet components - the fan adjusts its speed to the required value Easy to use: - integrated funnel - self-sealing hose connector with quick coupling - drain cock High quality components: - touchscreen controller with high quality glass screen and integrated digital flow and fill level indicators - components from renowned German manufacturers - refrigeration unit: completely hermetically sealed, air cooled, low maintenance High operational reliability: - thermal overload protection - dry-running protection - optical and acoustic alarm - error messages are displayed in plain text Proven standard: - MOD bus interface Technical features: Operation from -10°C to +40°C Control accuracy +/- 0.5K Cooling capacity in watts at + 20°C 1200W; at + 10°C 850W; at -10°C 400W Circulation pump: flow rate 12 l / min Flow pressure: 2.9 bar External dimensions [LxWxH]: 35 x 44.5 x 66 cm Weight: 41 kg Ambient temperature from +12°C to +30°C Electrical connection: 230 V / 50 Hz Max current: 3.5 A Coolant tank from 2.5 to 9.5 l Fitting for 12 mm hose

€3,979.00 ex VAT
€4,735.01 incl. VAT if applicable
Italy
industrial chillers, laboratory modules
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser Binary pump Autosampler Thermostatted colomn compartme (more)nt Variable wavelength detector Vacuum degasser: The Agilent 1100 HPLC Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Binary pump: Flow Precision: <0.3 % RSD (typically <0.15 % RSD) Flow Range: Setpoints from 0.001 to 5.0 ml/min,  in 0.001 ml/min increments Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) Pulsation: <2 % amplitude (typically <1 %) at 1 ml/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi) Compressibility compensation: User selectable, based on mobile phase compressibility Delay volume: 180 – 480 µl (600-900 µl with mixer) dependent on back pressure Recommended pH range: 1.0 – 12.5. Solvents with pH <2.3 should not contain acids which attack steel Well-plate autosampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl  Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Variable wavelength detector: Detection type: Double beam photometer Light source: Deuterium lamp Wavelength range: 190 – 600 nm Wavelength accuracy: ± 1 nm Bandwidth: 6.5 nm Linearity:> 2AU (5%) upper limit Flow cell standard: 14 µl volume, 10 mm cell path length, 40 bar

€7,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]