Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
E2 Mass Standard - Stainless Steel Wire -2 mg
Supplier
Radwag
Location
Radom - Poland
Price
€59.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag E2 Mass Standard - Stainless Steel Wire -2 mg

Radwag€59.00 (ex VAT)
item image

Description by the supplier

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research.


E2 class standard: stainless steel wire

Nominal value: 2 mg

Material: stainless steel


High Precision of measurements


The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component.


Stability over Time


An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry.


Calibration and Strict Quality Control


Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy.


Versatility of Applications


E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements.


Applications


1.

Analytical Laboratories


In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application.


2.

Pharma Industry


In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances.


3.

Scientific Research


In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results.


4.

Metrology Industry


In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards.


E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag F1 Mass Standard - Flat Polygonal Sheet - 10 mg-cover
Radwag F1 Mass Standard - Flat Polygonal Sheet - 10 mg

F1 class mass standards are exceptional measuring tools that represent the pinnacle of precision in  (more)the field of metrology. Classified as F1 metrology class, they are perfect for advanced applications where every detail of measurement is of paramount importance. F1 mass standard: flat polygonal sheet Nominal value: 10 mg Material: nickel silver F1 Class Mass Standards – Key Features Highest Precision and Accuracy - F1 class mass standards are characterized by absolute measurement precision and extraordinary accuracy. They are designed to meet the most stringent standards for acceptable deviation from actual weight. Stability under Difficult Conditions - An important feature of F1 class mass standards is their ability to maintain measurement stability even under harsh environmental conditions. The standards of this class are resistant to changes in temperature, humidity and other factors that affect the precision of measurements. Calibration in Accordance with International Standards - The calibration process for F1-class mass standards is rigorous and in accordance with international standards. This ensures that standards of this class are globally recognized and can be used in different countries. Specialized Construction Materials - F1-class standards are often made of materials with unique physical properties. This provides them not only with precision, but also with durability and wear resistance. Application 1. Industrial Metrology F1 class mass standards are used in metrology laboratories engaged in the testing and maintenance of measurement standards. 2. Scientific Research In scientific research, especially in high-precision fields such as physics and astronomy, F1-class mass standards are a key tool. 3. Aerospace Industry In the precision mass measurements required by the aerospace industry, F1-class standards guarantee reliability and accuracy. 4. Calibration Laboratories In calibration laboratories where uniformity and precision are a priority, F1-class mass standards are the standard of excellence. F1-class mass standards are synonymous with the highest quality and precision in the field of metrology. Their use is crucial where even the slightest deviation from the standard can carry unpleasant consequences. They are tools for advanced applications that contribute to raising standards in the field of mass measurement.

€18.00 ex VAT
Poland
mass standards
People are watching right now:
Radwag MA 50/1.5Y.NS Moisture Analyzer-cover
Radwag MA 50/1.5Y.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
moisture analysers, balances
IKA T 65 digital ULTRA-TURRAX-cover
IKA T 65 digital ULTRA-TURRAX

IKA T 65 digital ULTRA-TURRAX Speed Range 1,000 to 9,500 RPM Viscosity max. 5,000 mPas Volume range  (more)(H2O) 2 - 50 l Features - Wide speed range from 1000 to 9500 rpm for high circumferential speeds with small rotor diameters - Digital speed display and electronic speed control for precise operation - Electronic overload protection ensures device safety - Easy exchange of dispersing elements via plug-in connectors - Optional stainless steel dispersing elements available for vacuum and pressure conditions - Stepless speed adjustment with a 7 segment LED speed display - Three rotor-stator configurations ensure versatility in applications Extremely powerful dispersing instrument for volumes from 2 - 50 l (H2O) for typical pilot plant stations with digital speed display. It offers a wide speed range from 1000 – 9,500 rpm that enables users to work at high circumferential speeds even with small rotor diameters. Three rotor-stator configurations guarantee a wide range of applications. Reproducible operations due to constant speed even with changes in viscosities.The device requires a 3-phase electricity supply in order to operate. The connection of the unit to the power supply must be done by a qualified electrician. Wiring diagrams are included in the manual for reference.INCLUDED: The IKA T 65 digital ULTRA-TURRAX includes: - T 65 digital ULTRA-TURRAX® - Rotor wrench - Hook wrench - Shaft wrench - Cable gland for switch cable (2 pcs.) - Hexagon L-wrench - 2 Year Manufacturer's Warranty

$11,761.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]