Adam Equipment ETB 8202E Equinox Precision Balance, 8200g, 0.01g

$2,846.00 (ex VAT)
item image

Description from the supplier

Adam Equipment ETB 8202E Equinox Precision Balance, 8200g, 0.01g


Capacity
8200g
Readability
0.01g
Repeatability
0.01g

  • Large, responsive 5’’ 800x480 pixel touch-screen display
  • Level indicator and adjustable feet ensure proper balance setup for optimum weighing results
  • Security slot for optional Kensington-type lock and cable to help prevent theft
  • Large, grade 304 stainless steel pan allows easy cleaning
  • RS-232 interface provides speedy connection to computers and printers
  • USB host for memory card
  • Built-in memory for storing products and settings
  • External calibration allows for verification and adjustment with weights ("I" models feature internal automatic calibration)
  • Selectable digital filtering helps minimize effects of vibration and disturbances
  • Security password control prevents unauthorized access
  • Printouts include date and time for data tracking within Good Laboratory Practices (GLP) guidelines
  • Preset tare function speeds the process of repetitive weighing
  • Parts counting with freely selectable sample sizes
  • Multilingual display allows use in many different countries
  • Memory accumulation totals results
  • Check weighing with audible alarm


The Adam Equipment Equinox Precision Balances deliver remarkable precision to labs that perform highly detailed testing. The Equinox is ideal for research and quality assurance facilities; science education; precision counting; and production and manufacturing applications needing exceptionally precise results. Twelve precision models offer capacities from 360g to 8200g and readabilities of 0.001g and 0.01g. A color touch screen display provides intuitive operation, with icon-driven menus and readily accessible applications and functions. The five-inch screen is generously sized, offering 800 X 480-pixel resolution for excellent visibility.

  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 5 Year Manufacturer's Warranty

Product details

ModelETB 8202e
Capacity8200g
Readability0.01g
Repeatability (S.D.)0.01g
Linearity (+/-)0.03g
Minimum Weight (USP, typical)20g
Pan Size7.3"x7.3" / 185x185mm
Weighing Unitsg, mg, lb, oz, ct, GN, dwt, mm, ozt, T, tl.H, tl.S, tl.T, custom unit
Stabilization Time (sec)4
InterfaceRS-232, USB
CalibrationExternal calibration
DisplayTouchscreen with 0.5”/ 13mm-high digits
Power Supply24V 50/60Hz 500mA adapter
Operating Temperature10° to 30°C / 50° to 86°F
HousingABS plastic
Draft Shield ChamberN/A
Overall Dim.8.8"x14.7"x3.7" / 224x374x95mm (wxdxh)
Net Weight14.5lb / 6.6kg
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag AS 120.5Y Analytical Balance-cover
Radwag AS 120.5Y Analytical Balance

Do you need a balance that not only determines weight with impressive accuracy, but also performs a  (more)digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of balances: Digital Weighing Auditor Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the balance will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – An Innovative Way for the Balance to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the balance on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. Smart Min Weight The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. - Full data security - Electronic signatures - Validations - Electronic records - Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. Two-point adjustment Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€5,754.00 ex VAT
Poland
scales, analytical balances, balances
Radwag E1 Mass Standard - Flat Polygonal Sheet - 1 mg-cover
Radwag E1 Mass Standard - Flat Polygonal Sheet - 1 mg

E1-class mass standards are the elite in the world of metrology, because standards of this class rep (more)resent the highest level of precision and accuracy in mass measurement. The E1 classification is one of the most stringent standards that standards must meet in order to be considered the most advanced and trustworthy measurement tools. E1 - class standard: flat polygonal sheet Nominal value: 1 mg Material: aluminum What Are the Characteristics of the E1 Class? Highest Precision - The allowable deviation from the actual weight is minimal, making standards of this class ideal for applications where every gram matters. Stability and Repeatability - This guarantees a consistent level of accuracy over the long term. Accurate Calibration - Standards of this class must be regularly compared with other standards of known mass to confirm their measurement accuracy. Materials with Unique Properties - E1 class mass standards are often made of materials with exceptional physical properties, which makes them stable and resistant to changes in environmental conditions. Application 1. Analytical Laboratories In analytical laboratories where accurate measurements are crucial, E1 class mass standards are used to calibrate balances with the highest precision. 2. Pharmaceutical Industry In drug manufacturing, where even the slightest deviation from the standard affects quality, E1 class mass standards are irreplaceable. 3. Scientific Research In scientific research, especially in areas requiring the highest precision, such as physics or chemistry, E1 class mass standards are used to ensure reliable results. 4. Metrology Industry In metrology laboratories where research on E1 class mass standards alone is carried out, E1 class standards are the standard of excellence. Class E1 mass standards are not only measuring tools, but also a symbol of metrological excellence. Their use affects the quality of measurements in various areas of life because they provide precision that can be relied upon. They are a key element in the world of mass measurement, shaping standards and raising the bar for all measurement tools.

€87.00 ex VAT
Poland
mass standards
Radwag WLY 120/C2/K Precision Balance-cover
Radwag WLY 120/C2/K Precision Balance

If you buy a WLY series balance by July 31, 2024, you will receive each of these products along with (more) a FREE lifetime license for the Workflow Module. Precision Balance WLY Fast and accurate weight determination thanks to the duo: the WLY multifunction balance and the PUE7 weighing terminal. Ease of operation and maximum automation of the weighing process. Not just weighing But also parts counting, checkweighing, percent weighing, animal weighing, formulations and differential weighing. The power of WLY’s working mods. Use the potential Barcode scanners, receipt printers, label printers, RFID readers, PC equipment or an additional weighing platform – thanks to multipurpose software, WLY balance can work with all of them. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. The Workflow Module will improve work in your company. It enables developing a path of customized weighing process adapted to individual requirements of a particular production system, and next sending it to all weighing instruments cooperating with the E2R. The given process is started on the weighing instrument upon operator logging or after selecting a product, a formulation or an ingredient to which it is assigned. Modifications are made with use of convenient and intuitive interface. DIY with WLY With WLY you will Do It Yourself: You will program on-screen keys and functional keys You will program infrared proximity sensors You will design printouts You will design text data that is displayed in an indicator display. This balance is the result of a combination of our experience and true precision. Want to generate labels? You can. With Label Editor software, you will generate: Standard labels for single products C labels for cumulative containers CC labels for containers with cumulative containers. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€1,760.00 ex VAT
Poland
balances, precision balances
People are watching right now:
Adam Equipment ETB 6202I Equinox Precision Balance, 6200g, 0.01g-cover
Adam Equipment ETB 6202I Equinox Precision Balance, 6200g, 0.01g

Adam Equipment ETB 6202I Equinox Precision Balance, 6200g, 0.01g Capacity 6200g Readability 0.01g R (more)epeatability 0.01g Features - Large, responsive 5’’ 800x480 pixel touch-screen display - Level indicator and adjustable feet ensure proper balance setup for optimum weighing results - Security slot for optional Kensington-type lock and cable to help prevent theft - Large, grade 304 stainless steel pan allows easy cleaning - RS-232 interface provides speedy connection to computers and printers - USB host for memory card - Built-in memory for storing products and settings - External calibration allows for verification and adjustment with weights ("I" models feature internal automatic calibration) - Selectable digital filtering helps minimize effects of vibration and disturbances - Security password control prevents unauthorized access - Printouts include date and time for data tracking within Good Laboratory Practices (GLP) guidelines - Preset tare function speeds the process of repetitive weighing - Parts counting with freely selectable sample sizes - Multilingual display allows use in many different countries - Memory accumulation totals results - Check weighing with audible alarm The Adam Equipment Equinox Precision Balances deliver remarkable precision to labs that perform highly detailed testing. The Equinox is ideal for research and quality assurance facilities; science education; precision counting; and production and manufacturing applications needing exceptionally precise results. Twelve precision models offer capacities from 360g to 8200g and readabilities of 0.001g and 0.01g. A color touch screen display provides intuitive operation, with icon-driven menus and readily accessible applications and functions. The five-inch screen is generously sized, offering 800 X 480-pixel resolution for excellent visibility. INCLUDED: The Adam Equipment ETB 6202I Equinox Precision Balance, 6200g, 0.01g includes: - Power Cord - Operator's Manual - Manufacturer's Documentation - 5 Year Manufacturer's Warranty

$2,635.00 ex VAT
United States
balances
Ohaus ISRK04HDG Rocking Incubating Shaker-cover
Ohaus ISRK04HDG Rocking Incubating Shaker

Ohaus ISRK04HDG Rocking Incubating Shaker The Ohaus ISRK04HDG Incubating Rocking Shaker combines smo (more)oth rocking motion and general purpose incubation in one compact bench top unit.The ISRK04HDG is designed to incubate samples from 5° above ambient to 65° C to provide accurate and repeatable results. Rocking shakers provide a see-saw like motion. The ISRK04HDG features LED displays with touchpad controls. Both models include safety features that protect both the user and samples. Equipped with LED displays and touchpad controls for temperature, speed/tilt angle and time. Timer will display elapsed time or when programmed to a set time, will turn off when time reaches zero. Microprocessor control provides electronic tilt angle adjustment, allowing easy adjustment in 1° increments for tilt and 1 rpm for speed while unit is running. PID controller for precise temp. control. Units slowly increase speed to desired setpoint to avoid splashing, and feature overload protection. Audible and visual signals will activate when system detects an obstruction or overload of the tray.INCLUDED: The Ohaus ISRK04HDG Rocking Incubating Shaker includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer Warranty Ohaus ISRK04HDG Rocking Incubating Shaker Specifications Temperature RangeAmbient +5° C to 65° CTemperature Uniformity± 0.5° C at 37° CSpeed Range1 to 50 rpmSpeed Accuracy± 1 rpmTilt Angle0 to 15°Timer1 second to 160 hoursMaximum Weight Capacity10 lbs (4.5 kg)Tray MaterialAluminumTray Dimensions (L x W)10 x 7.5" (25.4 x 19.1 cm)Interior Dimensions (L x W x H)10.75 x 7.75 x 3.8" (27.3 x 19.7 x 9.7 cm)Overall Dimensions (L x W x H)17 x 11 x 10.5" (43.2 x 27.9 x 26.7 cm)Ship Weight22 lbs (10 kg)Comparison of ModelsSpecificationOhaus ISHD23HDGOhaus ISLD04HDGOhaus ISLDMPHDGOhaus ISLDMPHDGLOhaus ISRK04HDGOhaus ISWV02HDGTemperature RangeAmbient +5°C to 65°CAmbient +5°C to 65°CAmbient +5°C to 65°CAmbient +5°C to 65°CAmbient +5°C to 65°CAmbient +5°C to 65°CTemperature Uniformity± 0.5°C at 37°C± 0.5°C at 37°C± 0.5°C at 37°C± 0.5°C at 37°C± 0.5°C at 37°C± 0.5°C at 37°CSpeed Range15 rpm to 500 rpm100 to 1200 rpm100 to 1200 rpm100 to 1200 rpm1 to 50 rpm1 to 30 rpmSpeed AccuracyAbove 100rpm +/- 1%, Below 100rpm +/- 1 rpm± 2% of set speed± 2%± 2%± 1 rpm± 1 rpmOrbit25 mm (0.98")3 mm (0.12")3 mm (0.12")3 mm (0.12")N/AN/AMaximum Weight Capacity50 lb (22.7kg) @ 125 rpm, 10 lb (4.53kg) @ 500 rpm8 lbs (3.6 kg)4 microplates or 2 micro-tube racks4 microplates or 2 micro-tube racks10 lbs (4.5 kg)5 lbs (2.3 kg)Tray Dimensions (L x W)18 x 18" (457 x 457 mm)11 × 7.75" (27.9 x 19.7 cm)11 x 7.75" (27.9 x 19.7 cm)11 x 7.75" (27.9 x 19.7 cm)10 x 7.5" (25.4 x 19.1 cm)9.25 x 7.25" (23.5 x 18.4 cm)Overall Dimensions (L x W x H)23.5 in x 32.1 in x 26.6 in17 x 11 x 10.7"17 x 11 x 7.75"17 x 11 x 7.75"17 x 11 x 10.5"17 x 11 x 10.5".comparison-table tr td:nth-child(6) { background-color: #fffacd; }

$2,882.00 ex VAT
United States
shakers
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€8,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]