Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
hanna
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
not_applicable
Categories

Photometer for ammonia (NH3-N), with carrying case HANNA HI97700C

Biomatyx
item image

Description by the supplier

Photometer for ammonia (NH3-N), with carrying case HANNA HI97700C

New equipment in its original packaging

This portable photometer are designed with an innovative optical system that offer superior performance in accuracy, repeatability, and the amount of time that it takes to do a measurement.

The scale : 0.00 to 3.00 mg/L (ppm) NH3-N

Resolution : 0.01 mg/L (ppm)

Accuracy : ±0.04 mg/L ±4% of measured value

Light source : Tungsten lamp

Light source : silicon photocell @ 420nm

Cuvette type : round, diameter 24.6mm

Auto Off : after 15 minutes of non-use

Environment : 0 to 50°C (32 to 122°F); RH max 100%

The battery : 3 x 1.5V batteries

Size : 142.5 x 102.5 x 50.5 mm

Mass : 380 g

Reagent expiration : 11/2022

Product details
DetailMade in : Romania Serial No : 903200290111
About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Tekmar Dohrmann Velocity XPT Purge and trap-cover
Tekmar Dohrmann Velocity XPT Purge and trap

For sale: Tekmar Dohrmann Velocity XPT Purge and trap Condition: never used Including: installation  (more)kit + test reports from manufacturer     We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! ​Velocity XPT is more than a next-generation Purge and Trap system, it’s a revolutionary leap in technology. Advancements in Velocity XPT ensure the highest throughput with the least amount of downtime. From cutting sample cycle time nearly in half, to built-in intelligent diagnostics, Velocity XPT is the most productive Purge and Trap available today. With the Velocity XPT, you increase the sample throughput up to 100%. This nearly double sample throughput and increases the profitability of your VOC lab without the cost of an additional GC system. Patent-pending Accelerated Purge and Trap technology lets you independently control the flow rate during all modes, greatly reducing dry purge and bake times. Velocity XPT also provides a 25% reduction in trap cool down time after bake mode. Forward Focusing Chamber:  This patent-pending technology provides the highest resolution chromatography and superior peak shape for early eluting gases. By placing an expansion chamber after the trap during the desorption modes, analytes are focused into a tight band. When analytes are tightly focused prior to desorption into the GC, dramatic improvements in chromatography resolution are evident. The FFC also efficiently desorbs which greatly reduces carryover from run to run. Exceptional Inertness: Silcosteel tubing and Silcosteel-treated fittings throughout the sample pathway prevent loss of active, polar, and high-boiling compounds, and also resists corrosion. With the simple setup and accurate control, you save time by entering all parameters electronically with Electronic Flow Control where flow and pressure parameters remain precisely the same and are constantly monitored for accurate and reproducible results. Automatic Leak Check, Electronic Pressure Monitor: With intelligent diagnostics, Velocity XPT quickly and simply checks itself for leaks. If a leak is detected, system diagnostics help you isolate and pinpoint leaks. The Electronic Pressure Monitor uses a pre-set over pressure limit to identify potential pressure build ups and will shut itself down before damage can occur. The Guardian Foam Sensor option is a set of built-in photodiode-based sensors. If foam or liquid is detected at the top of the glassware, purge gas shuts down, the vent valve closes, and the sample drains. Guardian can be configured to automatically add an anti-foaming agent to the sample, allowing purge to continue and without re-running the sample.

Netherlands
general laboratory equipment other, analytical devices other
People are watching right now:
CTC Analytics HTC PAL MXY 04-01A Autosampler w/ Citation High Performance NMR-cover
CTC Analytics HTC PAL MXY 04-01A Autosampler w/ Citation High Performance NMR

This CTC Analytics HTC PAL MXY 04-01A Autosampler System was removed from a university lab where it  (more)was surplus to requirements. The system powers up and is in good cosmetic condition. Any issues with the individual modules are listed below. Included in the system are; 1x CTC Leap Technologies AutosamplerModel MXY 04-01A 1x CTC Injection UnitModel No. MZ 01-00F 1x CTC Stack Cooler DWModel MC 04-01 Rev. GThe drawer doors have come away (plastic screws snapped) 1x CTC Power SupplyPart No. MN 01-00 1x CTC Pelter ThermostatPart No. MN 03-00 1x CTC TerminalModel No. 01-00A 1x CTC Injection Valve Drive unitModel No. MV 02-01A 1x CTC Arm PlatformModel No. MR 034-02B 1x Motor Assembly Syringe PalModel No. MM 01-01F 1x Active Reverse Rinse UnitSer No. SDS1208007 1x XP power supplyModel AED45US24 1x Syringe Holder:Model No. MSU 014-00A The unit is in good cosmetic condition. 1x Citation High Performance Sample LoaderThe PC powers on and is in good cosmetic condition. There is a Leap Technologies program on the Sample loader Other Control Programs:• Solvent Conditioner Control 2.16•One Minute NMR 2.18.43•Citation Control 2.4 1x Protasis Desgasser 1x Reloatable Power TapModel PDU20BHVIEC 10R 8x IEC ports Accessories: 2x PAL System X Type Syringes:Part No. 20452/01 • 100µl Hamilton Gas tight glass Syringes2x 5.0ml 1x 1000µl 1x 0.25µl The units are in good cosmetic condition. 1x L-Mark glass Syringe:F/N 0.72(G22s)b51•50µl The unit is in good cosmetic condition (with needle) 100ml Wheaton Glass bottles: 3x with lids2x without lids The units are in good cosmetic condition. 500ml Glass bottles1x Simax (with lid) 1x Boro 3.3 (without lid) The units are in good cosmetic condition.

£2,000.00 ex VAT
United Kingdom
nmr spectrometers, automated liquid handling
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]